JMPServer/Login Registry Key
NAME
JMPServer/Login
DEFAULT
enabled
DESCRIPTION
By default the JMP server requires a successful login. This is achieved as
part of the protocol. Login is highly recommended. If the JNIOR is connected
to a private secure network this login requirement can be removed by setting
this Registry key to disabled. The change takes effect immediately. Note
that this requires that JMPServer/Anonymous be set.
SEE ALSO
HELP Topics:
JMPServer/Anonymous,
JMP
[/flash/manpages/registry.hlp:2317]